The accuracy level of the pressure transmitter refers to the maximum allowable error range of the difference between the pressure value and the reference value output by the pressure transmitter under certain conditions. According to international standards, the accuracy of pressure transmitters is generally divided into 0.1 class, 0.2 class, 0.5 class, 1.0 class, 1.5 class, 2.5 class, 4 class, etc. The corresponding measurement error ranges for each level are as follows:

Class 0.1 accuracy class: The permissible error range is ±0.05%. It is suitable for high-precision pressure measurement, such as chemical industry, laboratory, precision instruments and high-precision control systems and other important occasions.

Class 0.2 accuracy class: The permissible error range is ±0.1%. It is suitable for industrial occasions with high general requirements, such as compressors, pumps and some mechanical equipment.

Class 0.5 accuracy: The allowable error range is ±0.25%. It is suitable for general industrial pressure measurement and flow, liquid level and other parameter measurements.

Class 1.0 accuracy class: The allowable error range is ±0.5%. It is suitable for general industrial control and measurement of pressure, liquid level, flow rate and some measurement parameters.

Class 1.5 accuracy: The allowable error range is ±0.75%. It is suitable for general atmospheric pressure, air flow, heating furnace, fan and other industrial occasions.

Class 2.5 accuracy: The permissible error range is ±1.25%. It is suitable for rough industrial control and measurement of atmospheric pressure, liquid level and flow rate.

Class 4 accuracy class: The allowable error range is ±2%. It is suitable for large-scale equipment, pipelines and low-level instruments with low requirements.

When selecting a pressure transmitter, the pressure transmitter with the appropriate accuracy level should be selected according to the requirements of the actual application, weighing the accuracy level and cost.

TXYS general-purpose 2088 pressure transmitter uses 316L material diffusion silicon pressure core as a sensitive element, built-in processing circuit, after computer automatic testing, and uses laser resistor adjustment process for wide temperature and sensitivity compensation, the sensor millivolt signal is converted into standard voltage, current signal output, can be directly connected with computers, control instruments, display instruments, etc., there are 0.1 grade, 0.2 grade, 0.5 grade accuracy level optional.

2088 pressure transmitter

The piezoresistive pressure sensor with high stability and high reliability and the special circuit for the high-performance transmitter are selected, and the overall performance is stable and reliable, and the signal transmission can be carried out over long distances. It adopts industrial explosion-proof shell and digital compensation circuit, and the display output is stable.

Features:

●IP65 enclosure rating

●316L stainless steel diaphragm structure

●High-precision, all-stainless steel structure

● Digital pressure display, LED/LCD optional

●Strong anti-interference and good long-term stability

●Diversified forms and structures, easy to install and use

●Wide range of measuring range, can measure gauge pressure, absolute pressure and differential pressure

●Anti-vibration and shock-resistant

Basic parameters

Measuring range-100kPa... 0~10kPa... 160MPa
Type of pressureGauge pressure, absolute pressure
Power supply12-30VDC
Output signal4~20mA、485、4~20mA+hart
Operating temperature-40℃~85℃
Medium temperature-40℃~85℃
Storage temperature-40℃~100℃
Zero-point temperature drift±0.1%FS(-20℃~85℃)
Sensitivity: temperature drift±0.1%FS(-20℃~85℃)
Overload pressure150%FS
Mechanical vibration20g(20~5000HZ)
impact100g(11ms)
Comprehensive accuracyGrades 0.1, 0.2, and 0.5 are optional
break off margin100MΩ/250VDC
Response time≤1ms (up to 90% FS)
Long-term stability±0.1% FS/year
EMC surges(IEC61000-4-5)2KV
EMC static electricity(IEC61000-4-2) Contact discharge 8KV, air discharge 15KV
Ingress protectionIP65
Explosion-proof ratingIntrinsically safe explosion-proof Exia II.CT6 , Flameproof ExdII.CT6
MaterialHousing aluminum/stainless steel, diaphragm 316L
Media compatibleA wide range of media compatible with stainless steel

Selection Table

Model 2088 Pressure Transmitter
TXY□-□□□□/□□□□□□
Sensor type
S-GDiffusion silicon gauge pressure (typical)
S-ADiffusion silicon absolute pressure (conventional)
S-YStrain gauge gauge pressure (high pressure/high viscosity locations)
S-PSapphire gauge pressure (high and low temperature resistance)
S-LSapphire absolute pressure (high temperature and low temperature resistance)
S-BMonocrystalline silicon gauge pressure (high accuracy 0.1 class)
S-JMonocrystalline silicon absolute pressure (high precision class 0.1)
Process interfaces
00M20*1.5
01NPT1/2
02NPT1/4
03G1/2
04G1/4
07M14*1.5
Output signal
2Analog 4-20mA (two-wire system)
6485 Communications
9Analog 4-20mA (two-wire) + Hart communication
Enclosure type
XThe 2088 body is fitted with conventional fittings
Y2088 body with high temperature fitting (**200°C steam)
Z2088 Body with Clamp Fitting (φ 50.5)
Live display
NNo headers are displayed
AWith digital tube (LED) display head
YWith liquid crystal screen (LCD) display header
Accuracy class
1Level 0.1
2Level 0.2
3Level 0.5
Special Requirements (Multiple Options)
notNo special requirements
iIntrinsically safe explosion-proof Exia IICT6
dFlameproof ExdIICT6
QFlush membrane sensor
L316L connector (304 connector not selected)
ATube Accessories (Mounting Brackets)
Q2Armoured cable explosion-proof gland (304 material)
D4Electrical interface NPT1/2 female thread (not selected as conventional M20*1.5)
YAll English nameplates
ENameplate in English and Chinese
ZNeutral nameplate
FRadial stainless steel housing (die-cast aluminum housing not selected)
GAxial stainless steel housing (die-cast aluminum housing not selected)
RangeSee the range selection table
Selection example: TXYS-G002/XY2i16 2088 pressure transmitter, gauge pressure, interface thread M20*1.5, output two-wire system
4-20ma current signal, with LCD screen display head, accuracy level 0.2, intrinsically safe explosion-proof type, range of 0-40Mpa
Detailed range selection table
encodeRangeencodeRangeencodeRangeencodeRangeencodeRange
270-10Kpa010-35Kpa020-70Kpa030-100Kpa050-350Kpa
470-0.6Mpa250-0.5Mpa260-1.6Mpa42-0.1-1.6Mpa220-2.5Mpa
230-4Mpa200-6Mpa580-8Mpa110-10Mpa380-16Mpa
130-25Mpa140-35MPa160-40Mpa920-50Mpa170-60Mpa
Special capacities can be customized